Technician A says heater temperature may be controlled by regulating the amount of coolant flowing Through the heater core. Technician B says heater temperature may be controlled by regulating the amount of air flowing through the heater core. Which technician is correct?
Question 2
Multiple Choice
The ambient temperature is 70° F and the humidity is low. What should the high side gauge pressure be (AC system on) ?
Question 3
Multiple Choice
Technician A says refrigerant leaks are most common where components join together. Technician B says many manufacturers put leak-tracing dye in the refrigerant systems of new vehicles. Which technician is correct?
Question 4
Multiple Choice
What must the technician do before checking an air conditioning system for refrigerant leaks using a black light?
Question 5
Multiple Choice
Technician A says AC system lines and hoses that are cold have lower refrigerant pressure than warmer lines and hoses. Technician B says frost on a system component usually indicates a refrigerant leak in that area. Which technician is correct?
Question 6
Multiple Choice
An air conditioning performance check requires a ________.
Question 7
True/False
If the performance test shows less than 45° F at the center vent, the AC is working normally.
Question 8
Multiple Choice
The outlet line from the evaporator should be ________.
Question 9
Multiple Choice
Technician A says oily residue on hoses, components, or fittings indicates an area where refrigerant may be leaking. Technician B says damaged condenser fins may cause inefficient air conditioning operation at all blower speeds. Which technician is correct?
Question 10
True/False
On a cold day it is normal for the thermostat to stay closed for more than 15 minutes.
Question 11
Multiple Choice
Technician A says electronic leak detectors make a noise when a leak is detected. Technician B says that often the same leak detector can be used for R-12 and R 134a. Which technician is correct?
Question 12
Multiple Choice
An AC system has had about 0.5 lbs of R-22 refrigerant added. What would this cause?
Question 13
Multiple Choice
Technician A says that evaporator leaks can be detected by installing dye into the system and looking for yellowish-green dye stains. Technician B says that a leak at the evaporator can be detected by removing the blower motor resistor pack and inserting an electronic leak detector probe into the air stream. Which technician is correct?
Question 14
Multiple Choice
Technician A says a thermostat which opens too soon can cause poor heater operation. Technician B says low coolant level can cause poor heater operation. Which technician is correct?
Question 15
Multiple Choice
It is 90°F in the shop and the humidity is high. What pressure will be shown on the high side pressure gauge (AC system on) ?
Question 16
Multiple Choice
Technician A says that with a properly operating air-conditioning system, the inlet to the compressor should be cold and the outlet from the compressor hot. Technician B says that the condenser should be hot and the evaporator cold. Which technician is correct?
Question 17
Multiple Choice
A customer complains that the heater works sometimes, but sometimes only cold air comes out while Driving. Technician A says that the water pump is defective. Technician B says that the cooling system could be low on coolant. Which technician is correct?
Question 18
Multiple Choice
Technician A says that one heater hose should be hot and the other hose cool if the heater is functioning okay. Technician B says that both hoses should be hot to the touch. Which technician is correct?