Exam 20: Cold-Formed Steel Construction

arrow
  • Select Tags
search iconSearch Question
flashcardsStudy Flashcards
  • Select Tags

In the identification mark on a CFS member "362S125- 30 (33)G40", the letter S implies that

(Multiple Choice)
4.8/5
(98)

Each cold- formed steel section is stamped with an identification mark, which gives its designation and three additional information items. Which are those additional items?

(Essay)
4.9/5
(85)

Is the R- value of a wood stud wall with 3- 1/2- in- deep studs and 3- 1/2- in. fiberglass insulation the same as a cold- formed steel (CFS)wall with 3- 1/2- in.- deep studs with the same insulation? Explain your answer.

(Essay)
4.9/5
(82)

In the identification mark on a CFS member "362S125- 30 (33)G40", the number 30 implies that

(Multiple Choice)
4.8/5
(72)

What is deflection track in a cold- formed steel (CFS)stud wall?

(Essay)
5.0/5
(86)

CFS members are generally used as framing members in exterior wall cladding in buildings of

(Multiple Choice)
4.8/5
(84)

Which of the following cold- formed steel (CFS)sections is punched with holes-studs, tracks, bridging channels, and furring sections? What is the spacing of punched holes and the reason for it?

(Essay)
4.9/5
(74)

The top track in a load- bearing CFS wall must be doubled in the same way as the top plate in a WLF wall.

(True/False)
4.8/5
(78)

What is the difference between a CFS member that is hot- dip galvanized and a member that is galv- annealed?

(Short Answer)
4.8/5
(65)

Non- load- bearing CFS walls in a reinforced concrete or steel frame structures are of two types: interior walls and exterior walls. Interior walls are faced with gypsum board on both sides. Are the exterior walls faced with the same material?

(Essay)
4.8/5
(85)

CFS framing for interior gypsum board partitions is designed for a minimum gravity load of

(Multiple Choice)
4.9/5
(62)

Name the three furring sections used in cold- formed steel (CFS)construction.

(Essay)
4.8/5
(81)

In which situations is load- bearing cold- formed steel (CFS)construction preferred for single- family residences?

(Essay)
5.0/5
(78)

The terms G40 and Cp40 refer to the same property of CFS members.

(True/False)
4.9/5
(82)

The use of CFS, as an alternative to lumber, in load- bearing residential applications, has found favor in some warm, humid areas of United States because CFS is

(Multiple Choice)
4.7/5
(73)

WLF walls, CFS walls are assembled on site on the floor of the building and subsequently tilted up and moved into position.

(True/False)
4.9/5
(79)

The term "STUF" is an acronym that includes various cross sections used in cold- formed steel construction. Explain what STUF stands for.

(Essay)
4.8/5
(81)

In which situations are bridging channels required in a non- load- bearing cold- formed steel wall, such as a partition wall?

(Essay)
4.9/5
(77)

A 20- gauge sheet steel is thicker than 22- gauge sheet steel.

(True/False)
5.0/5
(89)

In designing CFS interior gypsum board partitions, we can assume either a composite structural behavior or a noncomposite structural behavior. Of the two, noncomposite behavior is more conservative because it ignores the structural contribution of the

(Multiple Choice)
4.7/5
(74)
Showing 61 - 80 of 81
close modal

Filters

  • Essay(0)
  • Multiple Choice(0)
  • Short Answer(0)
  • True False(0)
  • Matching(0)