Question 1
Multiple Choice
When testing an external LUN with default mapping on two paths, performance appears constrained and the utilization of the RAID group in the external storage system never exceeds 35% busy no matter how many test threads are generated. You want to increase the utilization of the external RAID group. Which two actions will accomplish this task? (Choose two.)
Question 2
Multiple Choice
Your customer has an HDP pool dedicated to interactive production workloads. Which two applications are good candidates to share this HDP pool? (Choose two.)
Question 3
Multiple Choice
You are deploying an external storage system and its connection to a VSP G1000. The VSP G1000 has four external pools. You must ensure balanced utilization of the external storage system parity groups within each pool. What would you do to satisfy this requirement?
Question 4
Multiple Choice
DP-Vol LUNs are taken from an HDP pool deployed with 128 disks (16x4D+4D RAID groups) . Access is random read. Which combination of FC paths, LUN Queue Depth, and number of DP-Vols will result in a per-disk queue of 4 within this pool?
Question 5
Multiple Choice
Your VSP G1000 customer has an HDP pool with 600 GB drives and they need more IOPS in the pool. Which action will satisfy the requirement?
Question 6
Multiple Choice
Which two conditions will cause high Cache Write Pending on a VSP G8000? (Choose two.)
Question 7
Multiple Choice
A customer plans to migrate an interactive application from a VSP to VSP G1000. The application has consistent access across all its capacity with low hit rates and no particularly high I/O access areas. The application latency must be less or equal to 1.5 ms. Which configuration do you recommend to satisfy the requirements?
Question 8
Multiple Choice
In a database environment, the system administrator complains that high write response times are triggering frequent automated alerts. However, utilization for processor, paths, and array groups is low. Database users are not complaining. What causing this problem?
Question 9
Multiple Choice
A customer complains about high response times. This occurs frequently with bursts of write I/O at 6,000 IOPS for 10 second periods during each minute. The write response is 60 ms during these 10 second periods. The average IOPS rate reported by Hitachi Tuning Manager over 1 minute is 600. In this scenario, what is the average response time over 1 minute?
Question 10
Multiple Choice
A VSP G1000 customer is concerned about high VSD utilization alerts during their nightly backup and application maintenance window. To address their concerns, you want to inform them about the maximum acceptable utilization level range. What would be the range in this scenario?
Question 11
Multiple Choice
A VSP G1000 performance analysis shows that server response times for virtualized volumes are high, 100 ms and higher, but HDD utilization rates in an external HUS 150 never exceed 35%. There are no processor or path constraints in the configuration. The workload is steady and stable. Which two actions will optimize this configuration? (Choose two.)
Question 12
Multiple Choice
Which two statements are true regarding HDP pools? (Choose two.)
Question 13
Multiple Choice
Response times in an HDP pool have been increasing consistently with each additional workload during a large scale migration. The response times may become unacceptable with subsequent migrations. The purchase of additional equipment is an acceptable solution. What are two valid actions in this scenario? (Choose two.)
Question 14
Multiple Choice
For a VSP G1000 system serving a mission critical interactive workload, which two statements are true about VSD failover? (Choose two.)
Question 15
Multiple Choice
A customer has a VSP G800 storage system with an HDT pool with internal SAS drives and a virtualized third-party array using SATA RAID 6. The virtualized array is connected to the VSP G800 using four 8 Gbps FC paths. The customer reports performance problems on an OLTP application deployed on a virtualized server using the HDT pool. What are two reasons for this problem? (Choose two.)
Question 16
Multiple Choice
A customer has several Oracle databases with different workload profiles residing on old HUS systems. The customer wants to consolidate workloads on a new VSP G800 system to increase database performance and to reduce costs. Which configuration would you use to accomplish this task?
Question 17
Multiple Choice
A customer has an HDP pool with four array groups and 600 GB SAS drives operating at 85% utilization. Four array groups of the same configuration were added to the pool. In this scenario, which metric should be reviewed to validate optimal pool performance?
Question 18
Multiple Choice
You are recommending RAID 6 to a customer for a non-database HDT pool. What are two reasons for this recommendation? (Choose two.)
Question 19
Multiple Choice
A customer with a VSP G1000 is using HDT with SAS 15K drives and external storage. The customer wants the daytime response-sensitive workload to benefit from tiering. They also want to minimize the impact of relocations on the daytime operation itself. In this scenario, which action will satisfy the requirements?
Question 20
Multiple Choice
A user with a diskless VSP G800 uses ShadowImage from the G800 with a virtualized VSP G200 system. Application performance suffers during the frequent ShadowImage resynchronization operations. What should be done to reduce the impact of the ShadowImage throughput in this scenario?
showing 1 - 20 of 34