Services
Discover
Ask a Question
Log in
Sign up
Filters
Done
Question type:
Essay
Multiple Choice
Short Answer
True False
Matching
Topic
Trade & Technology
Study Set
Electrical Wiring Residential
Exam 30: Swimming Pools, Spas, Hot Tubs, and Hydromassage Baths
Path 4
Access For Free
Share
All types
Filters
Study Flashcards
Question 1
Multiple Choice
Switches must be at least ____ ft. from the inside wall of a spa or hot tub.
Question 2
Short Answer
A clearly labeled emergency shutoff switch for the control of the recirculation system and jet system for spas and hot tubs must be installed at a point readily accessible to the users and not less than ____________________ away and within sight of the spa or hot tub.
Question 3
Multiple Choice
Drownings have occurred when a person is trapped under water by the tremendous ____ at an unprotected drain in a swimming pool.
Question 4
True/False
Do not bond together metal raceways, metal piping, and other metal surfaces within 5 ft (1.5 m) of the inside walls of the spa or hot tub, unless separated by a permanent barrier, such as a wall or building.
Question 5
True/False
We are permitted to use a flexible cord-and-plug connection for fixed or stationary equipment associated with a permanently installed pool. Underwater luminaires are included in this permission.
Question 6
Short Answer
At least one 125-volt, 15- or 20-amp GFCI-protected receptacle must be installed no closer than ____________________ ft but not farther than 10 ft from the inside wall of a spa or hot tub.
Question 7
True/False
Where there are no metal parts in contact with pool water, there still is a need to bond the water to the pool deck to eliminate voltage gradients between the pool water and the deck.
Question 8
True/False
Where there are no metal parts in contact with pool water, there still is a need to bond the water to the pool deck to eliminate voltage gradients between the pool water and the deck.
Question 9
Multiple Choice
Switches must be at least ____ ft. from the inside wall of a spa or hot tub.
Question 10
True/False
A hydromassage bathtub constitutes more of a shock hazard than a regular bathtub.
Question 11
Multiple Choice
A receptacle that supplies power to a spa or hot tub must be ____.
Question 12
Short Answer
At least one 125-volt, 15- or 20-amp GFCI-protected receptacle must be installed no closer than ____________________ ft but not farther than 10 ft from the inside wall of a spa or hot tub.
Question 13
Short Answer
UL Standard 1563 establishes the maximum water temperature at 104 degrees F, and the suggested maximum time of immersion is generally ____________________ minutes.
Question 14
Multiple Choice
The branch-circuit conductor ampacity and the rating of the branch-circuit overcurrent devices must not be less than ____ percent of the total nameplate rated-load ampere rating of an electric pool water heater.
Question 15
Multiple Choice
The purpose of bonding together all metal parts and other conductive surfaces that are part of, in, and around a permanently installed swimming pool is to ____ voltage gradients in the pool and adjacent areas around the pool.
Question 16
Essay
Once you run conductors beyond (on the load side of) a GFCI device protecting that wiring, you are not permitted to have other conductors in the same raceway, box, or enclosure. Give two exceptions to this rule.