In ____, a pre-contrast image referred to as a mask image is first obtained and post-contrast images are then digitally subtracted from the mask image.
(Multiple Choice)
4.9/5
(75)
The range of the numbers in FPDs is defined as the window level and the center of the range is defined as the window width.
(True/False)
4.8/5
(75)
The output screen is coated with a ZnCdS phosphor that converts the photoelectrons into light.
(True/False)
4.8/5
(86)
The operational elements of a dynamic FPD involve three sequences, resulting in a single ____________________ that must be completed in at least 33 ms for fluoroscopy.
(Short Answer)
4.8/5
(88)
Which process produces a new image that is subsequently added to the original image to produce the final image, referred to as the edge-enhanced image?
(Multiple Choice)
4.9/5
(70)
The image intensifier tube has been developed to replace the conventional fluorescent screen of the early ____________________.
(Short Answer)
4.7/5
(78)
Dynamic FPD detectors were first used in GI tract fluoroscopy and then later in angiography.
(True/False)
4.8/5
(70)
Which of the following is an image-processing technique used to reduce the radiation dose to the patient?
(Multiple Choice)
4.8/5
(84)
The computer operates on the data it receives from the ADC in ____ format.
(Multiple Choice)
4.7/5
(84)
Digital fluoroscopy systems with an image intensifier and video camera (both television camera tubes and CCD cameras)in the imaging chain have been replaced with ____.
(Multiple Choice)
4.8/5
(86)
Which of the following changes the contrast and brightness of an image display?
(Multiple Choice)
4.8/5
(71)
A pre-contrast image, referred to as a(n)____________________ image, is first obtained and post-contrast images are then digitally subtracted from the mask image.
(Short Answer)
4.8/5
(81)
Which of the following was developed to solve the image quality problems imposed by the fluoroscopic screen of the early fluoroscopes?
(Multiple Choice)
4.9/5
(55)
____________________ subtraction involves the digital subtraction of images in time.
(Short Answer)
4.8/5
(87)
In the case of ____________________ scanning, 262.5 odd lines (one TV field)are first scanned, followed by 262.5 even lines (one TV field).
(Short Answer)
4.9/5
(81)
____ refers to the brightening of the fluoroscopic image using the image intensifier.
(Multiple Choice)
4.8/5
(79)
_________________ of the image in conventional fluoroscopy is an important feature of the image intensifier.
(Short Answer)
4.9/5
(77)
The purpose of ____________________ frame averaging is to reduce the noise present in an image by continuously displaying an image that is created by averaging the current frame with one or more previous frames of digital fluoroscopic image data.
(Short Answer)
4.9/5
(89)
Which system couples the video camera to the television monitor by means of a coaxial cable and control electronics?
(Multiple Choice)
4.9/5
(88)
Modern conventional fluoroscopy imaging units use a high frequency generator to ensure efficient production of ____________________.
(Short Answer)
4.9/5
(64)