Exam 5: Flat-Panel Digital Radiography

arrow
  • Select Tags
search iconSearch Question
flashcardsStudy Flashcards
  • Select Tags

Since there are different sizes of body parts to be imaged, different sizes of ____________________ are commercially available for clinical imaging.

(Short Answer)
4.9/5
(92)

The narrower the LSF, the better the ____________________ resolution.

(Short Answer)
4.9/5
(64)

Which of the following addresses the appearance of the image displayed on a monitor for viewing and interpretation by a radiologist?

(Multiple Choice)
4.9/5
(91)

Which of the following is a complex mathematical function that measures the ability of the detector to transfer its spatial resolution characteristics to the image?

(Multiple Choice)
4.8/5
(89)

Under random conditions it has been shown that the quantum efficiencies (based on the X-ray absorption properties of the detector converter materials)at 70 kV is about 67% for a-Se and 77% for CsI phosphor.

(True/False)
4.9/5
(82)

The raw digital data from a detector has a high image contrast simply because of the wide exposure latitude of the digital detector.

(True/False)
4.9/5
(73)

The flat-panel TFT digital detector is designed as a matrix of detector elements, each of which can be regarded as a(n)____________________.

(Short Answer)
4.8/5
(80)

Problems arising as a result of image ____________________ may also be related to the differences in the acquisition workstation and the higher-quality PACS workstation used by the radiologist.

(Short Answer)
4.8/5
(77)

A higher MTF value at a higher spatial frequency means that the detector provides better spatial resolution than lower MTF values at low frequencies.

(True/False)
4.9/5
(86)

An important imaging performance characteristic of a flat-panel detector that has an impact on clinical practice is image lag.

(True/False)
4.9/5
(68)

The dynamic range of a digital detector is the response of the detector to different levels of ____.

(Multiple Choice)
4.8/5
(81)

Which of the following deals with the efficiency of a detector to convert the x-radiation signal at its entrance window into useful image signal?

(Multiple Choice)
4.7/5
(74)

Which of the following describes the ability of the imaging system to resolve fine details present in an object?

(Multiple Choice)
4.8/5
(93)

Which concept examines the response of the image receptor (screen-film detector or digital detector)to the radiation falling upon it?

(Multiple Choice)
4.8/5
(83)

While indirect detectors use a phosphor, direct detectors use a(n)____________________.

(Short Answer)
4.9/5
(84)

All digital imaging systems have what is referred to as the limiting resolution, which is the spatial frequency limit that is obtained at an MTF value of 0.1.

(True/False)
4.8/5
(70)

Which of the following images is obtained initially from the detector and contains artifacts due to the bad detector elements?

(Multiple Choice)
4.8/5
(88)

At ____ kV, efficiencies are 37% for a-Se and 52% for CsI.

(Multiple Choice)
5.0/5
(75)

Which of the following plays a role in image display optimization?

(Multiple Choice)
4.9/5
(82)

Too much edge enhancement produces image noise and creates ____.

(Multiple Choice)
4.7/5
(78)