Exam 15: Dental Implants
Exam 1: Introduction to Restorative Dental Materials40 Questions
Exam 2: Properties of Materials43 Questions
Exam 3: Preventive Dental Materials39 Questions
Exam 4: Direct Esthetic Restorative Materials40 Questions
Exam 5: Dental Amalgam38 Questions
Exam 6: Finishing, polishing, and Cleansing Materials38 Questions
Exam 7: Cements42 Questions
Exam 8: Impression Materials38 Questions
Exam 9: Model and Die Materials39 Questions
Exam 10: Waxes37 Questions
Exam 11: Casting Alloys, wrought Alloys, and Solders38 Questions
Exam 12: Casting and Soldering38 Questions
Exam 13: Polymers in Prosthodontics38 Questions
Exam 14: Dental Ceramics38 Questions
Exam 15: Dental Implants38 Questions
Select questions type
The bone is prepared for an endosseous dental implant with special metallic burs driven at _____ speeds _____ water-cooling.
Free
(Multiple Choice)
4.8/5
(59)
Correct Answer:
D
High temperatures in bone during endosseous implant placement will:
Free
(Multiple Choice)
4.8/5
(81)
Correct Answer:
E
If the temperature during the osteotomy exceeds 37° C,then _____ could occur.
Free
(Multiple Choice)
4.9/5
(86)
Correct Answer:
D
Burs for preparation of the implant site are composed of special alloys of:
(Multiple Choice)
4.7/5
(85)
The prosthesis is most commonly screwed into place with a small screw that penetrates the top of the crowns and threads into the:
(Multiple Choice)
4.7/5
(77)
Increasing amounts of oxygen increase the _____ of commercially pure titanium alloys used for endosseous implants.
(Multiple Choice)
4.8/5
(82)
Which type of implant-supported prosthesis is most likely to fail?
(Multiple Choice)
4.9/5
(81)
An oxygen concentration of _____ wt % is used in grade 1 commercially pure titanium implant alloys.
(Multiple Choice)
4.9/5
(87)
Ceramic coatings improve bone-implant bond strengths.Their long-term stability in service is uncertain.
(Multiple Choice)
4.9/5
(71)
For most clinical situations,implant success rates are more than ____% as long as the implant osseointegrates initially and the clinical environment is not extreme.
(Multiple Choice)
4.9/5
(65)
Once the implant site is prepared in bone,the endosseous implant is placed by:
(Multiple Choice)
4.9/5
(66)
The thickness of most ceramic coatings on implants ranges from _____ microns.
(Multiple Choice)
5.0/5
(86)
Scratches or other disruption of the original manufacturer's oxide layer on the surface of endosseous implants are discouraged.Any contamination of the original surface will increase the risk of failure of the implant to osseointegrate.
(Multiple Choice)
4.8/5
(81)
Which of the following statements is(are)true about the surface of commercially pure titanium or titanium alloy?
(Multiple Choice)
4.8/5
(90)
Endosseous implants provide an esthetic substitute for a lost or missing tooth.They are placed to restore lost centric occlusion.
(Multiple Choice)
4.9/5
(77)
During the second stage of a two-stage implant placement,a second surgery is performed to remove the healing caps and:
(Multiple Choice)
4.8/5
(93)
A rate of horizontal bone loss greater than _____ mm per year is a sign of a failing implant.
(Multiple Choice)
4.7/5
(64)
Occlusal forces on natural teeth favor bone maintenance.However,occlusal loads on dental implants are transmitted to bone mostly by compressive forces that tend to cause resorption of the bone.
(Multiple Choice)
4.9/5
(82)
Showing 1 - 20 of 38
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)